CoolTool CoolTool has created during the last years a new standard in technical software for refrigeration and air conditioning: the huge amount of possibilities and complete calculations are searching for his equals.
CoolTool allows it, to make all important calculations in the field of refrigeration and air conditioning quickly, efficient and exact: from the estimation of air flow in the psichrometric chart over the cooling load for coldrooms and for air conditioning up to the complete design of all parts of huge plants.
CoolTool makes the user able to compare different solutions and variant design of the plants for the same problem and to choose the best: part lists, graphics, print out and the export-possibilities are easing the necessary documentation in the company.
Accordion 1
- Pipe layout for steel- and coppertubes, for suction-, discharge-, liquid-, expansion-, condensing and hotgas bypass line in consideration of pressure loss, velocity and particular run.
- Lay out double riser tube for proof oil return.
- Display of the thermodynamic process in the h, log p - diagram.
- Estimating of the energy consumption and CO2 emissions dependent on the construction and the performance of the plant
- more than 30 different refrigerants, calculation of the influence of the temperature glide for refrigerant blends.
- Compressor design in consideration of the necessary displacement, variation: reciprocating, scroll or screw; open, semi hermetic, or hermetic.
- Component design for eighteen different kinds of parts from the CoolTool Database, graphical display of the parts.
- Creation of part lists for tubes, valves, aggregates and reductions.
- Creation of an automatic system flow diagram with selected parts.
- Summary of all relevant technological and ecological information in the printout
- Project and part list management.
- Interface to CoolTool cold room, air conditioning load, to CoolTool h,x - chart; Interface to CoolDraw for electric wireing and system flow diagrams.
Accordion 2
- Pipe lay out for steel- and copper tubes, for suction-, discharge-, liquid-, expansion- and condensing line in consideration of pressure loss, velocity and particular run for high- and low pressure part of the plant.
- Display of the thermodynamic process in the h, log p - diagram.
- Estimating of the energy consumption and CO2 emissions dependent on the construction and the performance of the plant.
- More than 30 different refrigerants, calculation of the influence of the temperature glide for refrigerant blends.
- Calculation and display of the optimum average pressure.
- Compressor design in consideration of the necessary displacement, variation: reciprocating, scroll or screw, open, semi hermetic, or hermetic.
- Component design for eighteen different kinds of parts from the CoolTool Database, graphical display of the parts.
- Creation of par tlists for tubes, valves, aggregates and reductions.
- Summary of all relevant technological and ecological informations in the printout.
- Project and part list management.
- Interface to CoolTool cold room, air conditioning load, to CoolTool h,x - chart; Interface to CoolDraw for electric wireing and system flow diagrams.
Modul 3: Compound plants with direct evaporation
- Pipe lay out for steel- and coppertubes, for suction-, discharge-, liquid-, expansion- and condensing line in consideration of pressure loss, velocity and particular run.
- Tube framework for up to 40 evaporators possible.
- Graphic illustration and print out of the tube framework: CoolTool quick scheme or detailed drawing in a ground plan.
- Lay out double riser tube for proof oil return.
- Display of the thermodynamic process in the h, log p - diagram.
- Estimating of the energy consumption and CO2 emissions dependent on the construction and the performance of the plant.
- More than 30 different refrigerants, calculation of the influence of the temperature glide for refrigerant blends.
- Compressor design in consideration of the necessary displacement, variation :reciprocating, scroll or screw, open, semi hermetic, or hermetic.
- Component design for eighteen different kinds of parts from the CoolTool Database, graphical display of the parts.
- Creation of partlists for tubes, valves, aggregates and reductions.
- Project and part list management.
- Summary of all relevant technological and ecological information in the printout.
- Interface to CoolTool cold room and air conditioning load. Interface to CoolTool h, x - chart. Interface to implement CoolDraw for electric wireing and system flow diagrams
Modul 4: Compound plants with secondary refrigerants
- Pipe lay out for steel-and copper tubes, for flow- and return line in consideration of pressure loss, velocity
- Tube framework for up to 40 cooler possible.
- Variation of every single tube possible.
- Graphic illustration and print out of the tube framework: CoolTool quick scheme or detailed drawing in a ground plan.
- Calculation of pressure drop of the heat exchanges/fan coils.
- Consideration of the hydraulic balance and pressure regulations valves.
- Calculation of the mixture from necessary freeze security.
- Component design for seven different kinds of parts from the CoolTool Database, graphical display of the parts.
- Main information for pump lay out.
- Creation of par tlists for tubes and reductions.
- Project and part list management.
- Interface to CoolTool cold room and air conditioning load. Interface to CoolTool h,x – chart. Interface to implement CoolDraw for electric wireing and system flow diagrams.
Modul 5: Compound plants with flooded evaporation
- Pipe lay out for steel- and copper tubes, for suction-, discharge-, liquid-, expansion- and condensing line in consideration of pressure loss, velocity and particular run.
- Pipe lay out on the evaporator side for steel- and copper tubes, for flow- and return line in consideration of pressure loss, velocity and particular run.
- Tube framework for up to 40 evaporators possible.
- Consideration of two phase flow.
- Variation of every single tube possible.
- Graphic illustration and print out of the tube framework: CoolTool quick scheme or detailed drawing in a ground plan.
- Lay out double riser tube for proof oil return.
- Display of the thermodynamic process in the h, log p - diagram with consideration of the circulation rate.
- Estimating of the energy consumption and CO2 emissions dependent on the construction and the performance of the plant.
- More than 30 different refrigerants, calculation of the influence of the temperature glide for refrigerant blends.
- Compressor design in consideration of the necessary displacement, variation reciprocating, scroll or screw, open, semi hermetic, or hermetic.
- Component design for eighteen different kinds of parts from the CoolTool Database, graphical display of the parts.
- Creation of part lists for tubes, valves, aggregates and reductions.
- Project and part list management.
- Interface to CoolTool cold room and air conditioning load. Interface to CoolTool h, x - chart. Interface to implement CoolDraw for electric wireing and system flow diagrams.
Modul 6: h,x - chart for handling of air humidity
- Graphic display of the connection of temperature, relative and absolute humidity, enthalpy and density as Mollier or Ashrae.
- Zoom of the graphic display.
- Lay out double riser tube for proof oil return. Permanent calculation of the properties by moving the mouse.
- Calculation of the properties for condition change.
- Mixture of two air flows.
- Calculation of latent and sensitive power.
- Display and calculation of complete air process with cooler, heater and humidifier.
- Variation of all important process points with mouse scroll buttons and immediate calculation and graphic display in the chart.
- Output of the calculation data to CoolTool plant design.
- Print out h, x-chart in colour.
Modul 7 : Cooling load for cold rooms
- Necessary cooling load from different shares in consideration of temperature,
- specific heat capacity before and after solidification, solidification enthalpy and respiration heat.
- Cooling good database with editor.
- Consideration of the air exchange rate from the number of entries.
- Outside- and inside air condition with relative humidity.
- Calculation of the temperature difference in the evaporator.
- Evaporator design in consideration of the electric power of the fan from the CoolTool database.
- Individual construction of wall with calculation of the heat transmission from building material database.
- Output of the calculation data to CoolTool plant design.
- Data of the storage are saved together with the plant information in the main projekt in the CoolTool plant design software.
Modul 8: Cooling load for air conditioning
- Necessary cooling load from shares of the different internal and external loads like heat transmission, sun radiation, air exchange, persons and electrical power.
- Consideration of the latent and sensitive enthalpy.
- Change of the geografical data for calculation of the specific sun radiation.
- Consideration of the store capacity of the walls.
- Consideration of the air exchange with outside and inside air humidity.
- Individual construction of wall with calculation of the heat transmission from building material database.
- Output of the calculation data to CoolTool plant design.
- Data of the storage are saved together with the plant information in the main projekt in the CoolTool plant design software.
Modul 9 : CoolDraw with technical libraries
- Drawing tool with zoom function.
- Graphic library EN 1861 for system flow diagrams.
- Graphic library DIN 40 900 for electric wire schemes.
- Graphic library with pictos of components.
- Extension of the library by the user is possible.
- Single files can be saved.
- Connected with CoolTool projects.
- Colored printout.
Modul 10: HeatPump Pro Heatpump facilities
- heat demanded pipe dimension for steel- and copper pipe for Suction, pressure,liquid, injection and condensate pipeline after pressure loss, flow speed and part load operation.
- Dimensioning double rising pipelines with critical oil return, Economizer/Steaminjection operation, hot gas defrosting
- Display of the thermo-dynamic comparative process in the h, log p – diagramme more than 30 refrigerants, consideration of the Temperaturglides on mixed refrigerants
- Compressor dimensioning according type possible: Piston, croll or Screw, openly, semi-hermetic or full-hermetik component dimensioning from the CoolTool database with graphically displaying of the components
- Compilation of parts list for conduits, armatures, aggregates and reductions
- Automatically creation of a RI - Assembly-line Sketch with the chosen components
- Conformance Declaration of Pressure Equipment Directive (PED) and ECO Design Directive
- Project and part list management
- Interface to CoolTool climate load and heating load calculation and h, x – diagram
- Determine operating expenses-/energy consumption with worldwide available climate data
Modul 11: CoolTool plant calculation
- Masterdata for determination of assambling time and business calculation.
- Parts lists export and assign assembly time after type, size and pipe connection
- Stammdaten für Kupfer-, Stahl, PVC- und GF-Rohr, bis zu 15 Positionen für Kleinteile je Rohrdimension
- Gaining data from cool tool parts list with selectfunktion
- Summarize of the same positions
- Whole calculation of all components with profit margins for material and wages
- Copy and paste export to MS Excel
- Export function of ASCII/ANSI file format
Modul 12: CoolTool EnerSIm Pro Energy optimisation
- Simulation of the comparative process from one-stage, multicompressor systems and refrigerant plants
- Operating expenses analysis with variable condensing temperature in the annual and day-by-day way
- Masterdata for plant utilisation and run time
- Variations of controlling type, winter regulation, plant maintenance, facility filling
- Climate data throughout Europe/Worldwide
- Documentation and graphic representation
Modul 13: CoolTool MonoFlow
- CoolTool for Monoflow Parallel/Booster systems with direct evaporation in two temperature levels
- Pipe lay out for steel- and copper tubes, for suction-, discharge-, liquid-, expansion - and condensing line in consideration of pressure loss, velocity and particular run for two temperature levels
- Tube framework for up to 80 evaporators possible.
- graphic illustration and print out of the tube framework in a ground plan
- Lay out double riser tube for proof oil return..
- Display of the thermodynamic process in the h, log p - diagram.
- Estimating of the energy consumption and CO2 emissions dependent on the construction and the performance of the plant
- more than 40 different refrigerants including CO2 trans critical, calculation of the influence of the temperature glide for refrigerant blends..
- Compressor design in consideration of the necessary displacement, variation :
- reciprocating, scroll or screw, open, semi hermetic, or hermetic. .
- Creation of part lists for tubes, valves, aggregates and reductions
- Creation of an automatic system flow diagram with selected parts
- Project and part list management.
- Summary of all relevant technological and ecological information in the printout
- Summary of all relevant technological and ecological information in the printout
- Interface to CoolTool cold room and air conditioning load. Interface to CoolTool h, x - chart. Interface to CoolDraw for automatic system flow diagrams
Modul 14: CoolTool Database
- More than 8000 parts from AC&R, Alco, Airwell, Alfa Laval, Bitzer, Bock, Castel, Carly, Carrier, Copeland, Danfoss, Delchi, Dorin, Eco, ESK, FAS, Frascold, Flica, Friga-Bohn, GAR s.r.l., Goedhart, Hansa, Helpman, Honeywell, ITE, Küba, L’Unite, Maneurop, Necchi, Roller, Searle, Sporlan, Technibel,... to be calculated, designed and compared with the software.
- Selection of the compressors by reel thermodynamic conditions.
- Selection of the evaporators by consideration of the EUROVENT Standards.
- Valves are calculated by using the k, v – value and the pressure loss.