TURBOCOIL® heat exchanger
The extraordinarily efficient performance of the heat exchanger is due to the optimum combination of special profile aluminium fins and internally helically-grooved tubes.
Turbocoil®
High-efficiency heat exchanger with TURBOFIN® (louvered profile) aluminium fins and copper tubes with internal helical grooves.
STEEL Protected
Corrosion resistant epoxy-polyester coated galvanized steel casing.
Safetubes System®
Patented coil suspension system which prevents any contact between the tubes and the support structure, protecting the tubes during transport, installation and operation.
SMART®
Special patented structure for V-shape products. Provides rigidity, reduced weight and improves air circulation.
SUPER Silent Efficient
Very quiet air cooled condensers and dry coolers with reduced energy consumption.
Turbofin®
Aluminium TURBOFIN® fins with high-efficiency turbulator louvres to increase heat transfer coefficient.
WHISPERER®
Compact silencer designed and developed by LU-VE. Combined with EC fan motor, provides drastic reduction of sound level by up to 6 dB(A) and up to 19% reduction of electricity consumption.
EC
High-efficiency electronic axial motor, controlled by a 0-10 V signal to guarantee high energy savings and low sound level.
FAN MOTOR REGULATION
System to control fan speed in relation to thermal requirements.
DRY&SPRAY®
System to spray high pressure atomized water direct onto the coil to maximize the performance of dry coolers, gas coolers and condensers. With the DRY&SPRAY® system it is possible to obtain temperatures of the condensate fluid or water that are less than the dry bulb temperature of the air. This product is therefore a valid alternative to evaporative towers, with important advantages in terms of water consumption and energy savings, as well as excluding the risk of environmental contamination (Legionella).
WATER SPRAY System®
System to spray low pressure nebulized water to maximize the performance of condensers, gas coolers and dry coolers with a consequent reduction of dimensions, sound level and energy consumption.
ATEX
Special configuration in compliance with the ATEX 94/9/CE standard for explosion risk zones.
ISOLATOR SWITCH
Electromechanical disconnector switch to turn off individual fan motors during maintenance.
ANTI-VIBRATION PADS
Antivibration pads.
WIRING
Fan motor wiring in junction box.
PROTECTION GRILLE
Grille to protect the coil from accidental impact during transportation and operation.
OPPOSITE CONNECTIONS
Connections on the opposite side to standard.
FAN SECTION DIVISIONS
Fan section divisions to separate the air flow of each individual fan motor to improve air distribution over the coil during ON/OFF regulation.