HBCP is a simplified variant of the HBX vapor quality sensor used at the compressor inlet. HBCP can provide an alarm, when the liquid content in the gas exceeds the critical set point. This alarm and a measured value are typically sent to a PLC. This information can be used for controlling the system and stop the compressor to avoid liquid slugging.

HB PRODUCTS
Rod Style – Compressor Protection HBCP

HBCP is a simplified variant of the HBX vapor quality sensor used at the compressor inlet. HBCP can provide an alarm, when the liquid content in the gas exceeds the critical set point. This alarm and a measured value are typically sent to a PLC. This information can be used for controlling the system and stop the compressor to avoid liquid slugging.

The sensor can prevent liquid refrigerant from entering the compressor and causing damage and break down. Especially in larger systems with several evaporators it can be difficult to control all unit and this sensor can be used for both surveillance and trouble shooting.

The HBCP and the vapor quality sensor measures the amount of liquid in the gas passing through the sensor and react instantly.

The sensor is available in two versions:

Rod style sensor which must be installed in an elbow after at the end of a horizontal pipe. The sensor must be located at the bottom of the pipe where the liquid flows. The sensor will not work if located at the middle of the pipe or in a vertical pipe.

The strainer house sensor is installed in an empty strainer house, and it measures all the liquid flowing on the walls.

The rod style version is available in two lengths 150 and 300 mm suitable for different pipe sizes. The longest version is typically needed for pipes larger than 2”

Features

  • The sensor protects the compressor against damage in the event of liquid hammer from the system.
  • Setting up the sensor using a PC allows for adjustments to match the system and the compressor.
  • Instantaneous reaction without delays.

TECHNICAL SPECS

Power supply
Voltage 24 V AC/DC + 10%
Current consumption – sensor only* 600 mA
Plug connection M12, 5 pins – DIM 0627
Output
Output type PNP-1 A
Output function NC or NO
Environmental conditions
Ambient temperature -30°C…+50°C
Max. pressure 100 bar
Waterproof rating IP65
Vibrations IEC 60068-2-6 (4g)
Mechanical specifications
Thread connection 3/4” & 1″ NPT / BSPP
Material – mechanical parts AISI 304 / PTEE
Material – electronic parts Nylon 6 (PA)
Dimensions See drawing
Approvals
CE EN 61000-2
Cable
Cable size 5 m – 3 x0.25 mm2
Cable glands PG7 / M8
Cable resistance 500 Ohm/Km
Indication
LED Indication Green, yellow, and red
Configurations
Type of configuration With the HB Tool
Tool to be used HBCP or HBX software
* Total consumption is sensor consumption plus output and it depends on ambient temperature.

TYPES

Pipe size (compressor line) Length Connection Ordering code
2″ 150 mm 3/4″ NPT HBCP-1.5-2
2″ 150 mm 3/4″ BSPP HBCP-1.5-6
> 2″ 300 mm 3/4″ NPT HBCP-3-2
> 2″ 300 mm 3/4″ BSPP HBCP-3-6
> 2″ 300 mm 1″ BSPP HBCP-3-8
> 2″ 300 mm 1″ NPT HBCP-3-9
Electronic Part Must be calibrated on-site HBCP-EL