AbTehnic Profesional

SCAEY FOUR-R410A SCROLL COMPRESSORS

SCAEY FOUR-R410A SCROLL COMPRESSORS
  • Multifunction units for 4-pipe systems
A.C.M. KALTE KLIMA
SCAEY FOUR-R410A SCROLL COMPRESSORS

FRAME

Self-supporting galvanized steel frame protected with polyester powder painting. Panels are easily removable for maintenance and service activities.

COMPRESSORS

Hermetic “scroll” type with overload protection by a klixon and complete with oil sight glass and crankcase heater.

They are installed on vibrations absorbing rubber and placed within a close compartment to reduce sound level and to allow service and maintenance activities while unit is in operation.

COOLING EXCHANGER

Braze welded plate type with two independent refrigerant circuits and one water circuit. The circuit is made to guarantee an homogeneous cooling of all the water flow even during partial load.

The insulation is made of flexible closed-cells lining. As protection, a flow switch is recommended to mount to stop the unit in case of no water circulation.

HEATING EXCHANGER

Braze welded plate type with two independent refrigerant circuits and one water circuit. The insulation is made of flexible closed-cells lining. As protection, a flow switch is recommended to mount to stop the unit in case of no water circulation.

OUTSIDE EXCHANGER

To maximize the heating operation with copper tube and aluminium finned coil. As option a protection grid is available.

FANS

Axial fans with aerodynamic outline blade section made of Al/Mg, directly coupled to a three phase electric motor with

external rotor. Included fans speed regulation (condenser control). A safety fan guard is fitted on air flow discharge.

REFRIGERANT CIRCUIT

Each unit is equipped with two refrigerant circuits. Each circuit includes: filter dryer, sight glass, Schrader service valve,

safety thermostat on the discharge line, 4-way valve, non return valve, two electronic thermostatic valves, solenoid

valve, liquid receiver and liquid separator on the compressor suction line. To protect the refrigerant circuit the following devices are installed: man. reset high pressure switch, aut. Reset low pressure switch, antifreeze thermostat.

ELECTRICAL BOARD

With protection grade IP54 the el. board is mounted in the compressor chamber. Service activities can be done while

the unit is in operation. It includes: main circuit automatic breaker with locking door device, compressors and fans

contactors and relé, auxiliary circuit transformer. Microprocessor to control automatically the unit with a visual

system to display the function as well as failures.

MULTIFUNCTION UNITS FOR 4-PIPE SYSTEMS

ACM Kälte Klima multi function chillers are defined by high-performance, versatility and model range to satisfy constantly growing requirements of modern market. Manufacturing industrial air-water chiller we focus on specific needs of the client to satisfy concrete goals and requirements in industrial air conditioning.


The SCAEY FOUR UNITS are designed to maximize the heating and cooling performances at the same time, wich means they offer high energy efficiency with top energy saving.


The SCAEY-FOUR units are the heat pump chiller air-water with axial fans, equipped with two independent hydraulic circuits, to supply simultaneously or separately hot water and chilled water. They are particularly suitable for use in four-pipe systems.

Acm Kälte Klima plans and produces different types of air conditioner close control units, able to satisfy a wide range of needs. All of them are characterized by an innovative design that allows to exploit the space and to reduce at minimum their dimensions.


In order to guarantee versatility, reliability and durability of all the Acm Kälte Klima’s solutions, the best materials and the latest technological innovations are used to realize the air conditioner close control units. They are planned also to allow a quick inspection during the maintenance operations.


The low weight of each close control unit makes it very easy to move it. Special precautions are considered also to reduce the noise and vibrations during the operation phase.